Install Vibro-PBF brackets between the structural wall and the floating metal stud framework at the specified locations within the wall construction.
Fix the bracket to the metal stud using standard self-tapping screws. No pass-through screw is required through the stud section.
Position the brackets to provide lateral support and improve wall stiffness while preserving acoustic separation between the floating wall system and the surrounding structure.
Ensure all connections maintain resilient isolation and avoid rigid acoustic bridges that could reduce the overall sound insulation performance of the wall assembly.