Vibro-WS is installed on floor or ceiling metal profiles (U-runners 50 mm, 75 mm or 100 mm wide) in line with the C-studs or continuously beneath the U-runner profile.
The supports are fixed to the metal profiles using bolts, while the profiles are anchored to the floor or ceiling using expansion bolts.
The cavities within the metal framework should be filled with sound-absorbing material such as mineral wool to improve acoustic performance.
Part or all of the lateral flaps can be trimmed along the integrated incisions to suit wall systems with reduced plasterboard thickness.
A metal washer must be used at every fixing point to ensure correct load distribution and secure installation. All wall systems must remain fully decoupled from rigid structural connections to maintain maximum vibration isolation performance.