Install Vibro-UCB at the specified support locations using suitable anchors, threaded rods, or fixing hardware appropriate for the supporting structure.
The top Ø14 mm fixing hole accommodates suspension rods or anchor systems, while the M6 threaded connection provides a secure lower fixing point for the supported element.
Where required, the resilient isolation element may be pre-compressed by adjusting the top nut and washer assembly to achieve the desired installation condition.
Ensure all supported elements remain acoustically separated from adjacent structures to avoid acoustic bridges and maintain vibration isolation performance.